Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem
IIIa
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Modem4/ModemIIIa² Messages
Medical Alarm by User
(4-digit User)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM
+++ACC aaaa ID=iiii
h1rrlssssssaaaasUiiiit
<header>[#aaaa|NidiiiiMA]
Message
Medical Alarm by Point
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/MApppp]
Message
Medical Alarm Restore
(4-digit User / Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MED ALARM REST
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasRppppt
<header>[#aaaa|Nriaa/MHpppp]
Message
Memory Fail
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MEMORY FAIL
h1rrlssssssaaaasAsD13t
Missing Alarm
(2212)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa POINT=ppp
h1rrlssssssaaaasMspppt
Missing Alarm
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaUZppp]
Missing Alarm
(4-digit Point
)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaUZpppp]
Missing Alarm / Cross Point
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=a CG=gg POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaXMppp]
Missing Alarm / Cross Point
(4-digit Point
)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=aa CG=gg POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaXMpppp]
Missing Alarm from Recent
Closing
(2 min of close)
(No User)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaCMppp]
Missing Alarm from Recent
Closing
(2 min of close)
(No User / 4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaCMpppp]
Missing Alarm from Recent
Closing
(2 min of close)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=a ID=iii POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|Nria/idiiiCMppp]
Missing Alarm from Recent
Closing
(2 min of close)
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa ID=iii POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|Nriaa/idiiiCMpppp]
Missing Alarm from Recent
Closing
(2 min of close)
(4-digit User / Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa ID=iiii POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|Nriaa/idiiiiCMpppp]
Missing Alarm Exit Error
(No User
)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaEZppp]
Missing Alarm Exit Error
(No User / 4-digit Point
)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaEZpppp]