Conettix D6600 Manual de usuario Pagina 112

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 185
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 111
Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem
IIIa
112
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Table 98:
Modem4/ModemIIIa² Messages
Event
Device/Mode
Display/Explanation
Comments
322
Medical Alarm by User
(4-digit User)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM
+++ACC aaaa ID=iiii
h1rrlssssssaaaasUiiiit
<header>[#aaaa|NidiiiiMA]
New
Message
323
Medical Alarm by Point
(4-digit Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasAppppt
<header>[#aaaa|Nriaa/MApppp]
New
Message
324
Medical Alarm Restore
(4-digit User / Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MED ALARM REST
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasRppppt
<header>[#aaaa|Nriaa/MHpppp]
New
Message
325
Memory Fail
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MEMORY FAIL
h1rrlssssssaaaasAsD13t
<header>[#aaaa|NYX]
326
Missing Alarm
(2212)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NUZppp]
327
Missing Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaUZppp]
328
Missing Alarm
(4-digit Point
)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaUZpppp]
329
Missing Alarm / Cross Point
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=a CG=gg POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaXMppp]
330
Missing Alarm / Cross Point
(4-digit Point
)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=aa CG=gg POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaXMpppp]
331
Missing Alarm from Recent
Closing
(2 min of close)
(No User)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaCMppp]
332
Missing Alarm from Recent
Closing
(2 min of close)
(No User / 4-digit Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaCMpppp]
333
Missing Alarm from Recent
Closing
(2 min of close)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=a ID=iii POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|Nria/idiiiCMppp]
334
Missing Alarm from Recent
Closing
(2 min of close)
(4-digit Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa ID=iii POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|Nriaa/idiiiCMpppp]
335
Missing Alarm from Recent
Closing
(2 min of close)
(4-digit User / Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa RECENT CLOSING
+++ACC aaaa AREA=aa ID=iiii POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|Nriaa/idiiiiCMpppp]
336
Missing Alarm Exit Error
(No User
)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasMspppt
<header>[#aaaa|NriaEZppp]
337
Missing Alarm Exit Error
(No User / 4-digit Point
)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa MISSING ALARM
+++ACC aaaa EXIT ERROR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasMppppt
<header>[#aaaa|NriaaEZpppp]
Vista de pagina 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 184 185