Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem
IIIa
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Modem4/ModemIIIa² Messages
Status: Analog Service
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSTppppt
<header>[#aaaa|OriaaASpppp]
Status: Analog Service
(Level & Value)
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE
+++ACC aaaa AREA=aa POINT=pppp
+++ACC aaaa LEVEL=lll VALUE=vvv
h1rrlssssssaaaaSTppppt
<header>[#aaaa|Oriaa/lvlll/vavvvASpppp]
Status: Close by Area
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:CLOSING
+++ACC aaaa AREA=a
h1rrlssssssaaaaSCsssst
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSAspppt
<header>[#aaaa|OriaDFppp]
Status: Door Forced
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSAppppt
<header>[#aaaa|OriaaDFpppp]
Status: Door Left Open
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSIspppt
<header>[#aaaa|OriaDNppp]
Status: Door Left Open
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSIppppt
<header>[#aaaa|OriaaDNpppp]
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSFspppt
<header>[#aaaa|OriaFAppp]
Status: Fire Alarm / Cross Point
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSFspppt
<header>[#aaaa|OriaFAppp]
Status: Fire Alarm / Smoke
Detector
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa SMOKE DETECTOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSFspppt
<header>[#aaaa|OriaFAppp]
Status: Fire Alarm / High Temp
Sensor
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa HIGH TEMPERATURE SENSOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSFspppt
<header>[#aaaa|OriaFAppp]
Status: Fire Alarm / Waterflow
Sensor
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa WATER FLOW SENSOR
+++ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaSFspppt
<header>[#aaaa|OriaFAppp]
Status: Fire Alarm
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSFppppt
<header>[#aaaa|OriaaFApppp]
Status: Fire Alarm / Cross Point
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa CROSS POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSFppppt
<header>[#aaaa|OriaaFApppp]
Status: Fire Alarm / Smoke
Detector
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa SMOKE DETECTOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSFppppt
<header>[#aaaa|OriaaFApppp]
Status: Fire Alarm / High Temp
Sensor
(4-digit Point)
D6500 Mode:
dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM
+++ACC aaaa HIGH TEMPERATURE SENSOR
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaSFppppt
<header>[#aaaa|OriaaFApppp]
Comentarios a estos manuales