Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3.2.7 ADT SIA (Message Type S)
ADT SIA
Example
SIA Mode Description
<LF><CRC><S><sequence#><receiver#><line#>[#aaaa|<E><damm-dd-
yytihh:mm:ss>data]<CR>
Table 53: ADT SIA (Message Type S) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical redundancy check number.
Message Type S (capital S)
sequence# The message sequence number. The valid sequence number range is
0001 to 9999.
receiver# The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
account# The communicator's account number up to sixteen digits.
E Event Code (refer to Appendix G: ADT SIA Report Codes).
damm-dd-yytihh:mm:ss Date and time.
Data This field contains message data codes such as event type, area number,
point number, identification number.
Comentarios a estos manuales