Conettix D6600 Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 185
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
51
3.2.8 Caller ID (Message Type <TAB>)
SIA Example SIA Mode Description
<LF><CRC><TAB><sequence#><receiver#><line#>[#0000|&TTTTTTTTTTTTTTTT]<CR>
Table 54: Caller ID (Message Type <TAB>) Byte Description
Title Description
LF Standard line feed character.
CRC Cyclical Redundancy Check number.
Message Type <TAB>
sequence# The message sequence number. The valid sequence number range is
0001 to 9999.
receiver# The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6..
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
& Origin ID Block.
T Up to 16-digit Caller ID.
Figure 13: Message sent to Printer
30/04 17:00 L01 CLI 9563832510
Vista de pagina 50