Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3.1.12 DSC 4-3 (Message Type d)
DSC 4-3
Example
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
h d r r l s s s s s s a a a a s E s X Y Y t
Table 14: DSC-4-3 (Message Type d) Byte Description
# Title Description
1 Header Character
(
)
Optional. Check with the computer automation software for
compatibility.
2 Message Type d
3-4 Receiver Number Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-11 Spaces Six spaces.
12-15 Account Number Account number, four digits.
16 Space One space.
17 E Event Code, “A” as the default.
18 Space One space.
19 X Event code number.
20-21 YY Zone number.
22 Trailer Character Typically, this is HEX 14.